Sustainable Building Materials and Healthy Buildings: Why Developers Hold the Real Power

Short answer: the materials, insulation and ventilation you specify decide whether a building is healthy, efficient and easy to let. Airtight buildings without proper ventilation can trap pollutants and moisture, causing mould and complaints even with a good EPC rating. Developers, not only designers, control these choices.

Adapted from my April 2026 article for Property Investor News. Read the full article →

Book an initial complimentary 30-minute consultation

Why this is now a commercial risk

Tightening EPC requirements, mould and condensation in rented homes, and higher planning expectations around sustainability are no longer separate technical issues. They converge into one risk: buildings that comply on paper but perform poorly in use become harder to let, harder to sell and expensive to fix.

How building materials affect health

We spend around 90% of our time indoors, so indoor air, temperature and humidity matter as much as energy performance.

  • VOC emissions: some paints, adhesives, sealants, engineered timber and insulation release volatile organic compounds, especially after installation. Low-VOC alternatives exist but are often dropped in cost-driven procurement.
  • Airtightness without ventilation: better airtightness improves EPC ratings, but without a ventilation strategy it traps CO₂, pollutants and moisture. Approved Document F sets the minimum ventilation requirements.
  • Moisture and cold bridges: poorly chosen or installed insulation can trap moisture, and unresolved cold bridges create cold surfaces where condensation and mould appear.

Sustainable building materials worth considering

  • Low-VOC paints, adhesives and sealants as a standard specification, not an upgrade.
  • Natural and breathable materials such as timber, natural stone, lime-based finishes and sheep wool or wood-fibre insulation, which can help stabilise humidity.
  • Continuous insulation with resolved details, minimising thermal bridges.
  • Mechanical Ventilation with Heat Recovery (MVHR) in airtight buildings, to bring in fresh air without losing heat.

No material works on its own: performance depends on correct integration and installation.

Why developers hold the real power

Consultants advise, identify risks and propose solutions, but the final decisions on materials are made by the developer through procurement and value engineering. A high EPC rating does not guarantee a healthy building. Ventilation failures, condensation and poor air quality lead to maintenance costs, tenant turnover, potential claims and reputational damage.

How to get it right from day one

  1. Set performance requirements at inception: low-VOC materials, a ventilation strategy and moisture-safe details.
  2. Involve the architect, M&E engineer and specialists at concept stage, especially on refurbishments and conversions.
  3. Fix preferred specifications to avoid uncontrolled contractor substitutions.
  4. Judge decisions on whole-life performance, not just upfront cost.

Performance is profit

Fixing insulation, ventilation and fabric problems after completion costs far more than getting them right upfront. Healthier, defect-free buildings attract better tenants and buyers, reduce void periods and support planning and funding. Minimum compliance is no longer enough.

Related: Change of use and office-to-residential conversions · Building regulations drawings

Frequently asked questions

What are the most sustainable building materials?

There is no single answer: it depends on the building. Low-VOC finishes, responsibly sourced timber, natural stone, lime-based finishes and natural insulation such as wood fibre or sheep wool are good options when correctly detailed and combined with proper ventilation.

Can insulation cause mould?

Yes, if it is poorly chosen or installed, or if the building becomes airtight without adequate ventilation. Moisture gets trapped and cold bridges create surfaces where condensation and mould form.

Does a good EPC rating mean a healthy building?

No. A building can achieve a good EPC rating and still suffer from poor ventilation, condensation or indoor air quality problems. Health depends on materials, details and ventilation as well as energy performance.

Talk to a RIBA Chartered architect. Book an initial complimentary 30-minute consultation and we will tell you honestly what is achievable, what approvals you need and what it is likely to cost.

Book an initial complimentary 30-minute consultation · +44 (0)7760 639 338 · hello@luciapiccinini.com

Lucia Piccinini is the founder of LP ARKinnovation, a RIBA Chartered Practice working across London and beyond, including Chiswick, Hammersmith, Fulham, Chelsea, Kensington, Westminster, Tower Hill, Islington, Brentford, Hounslow, Richmond, Windsor and Maidenhead. ARB registered architect (085370D), RIBA Chartered Member and registered with the Ordine degli Architetti in Italy, with more than 15 years of practice across London, Florence and Milan. She writes a monthly column for Property Investor News, contributes to Fairness Magazine and speaks at property industry events. Press, articles and podcasts.

As a RIBA Chartered Practice, we work closely with private clients, property developers, and commercial partners—guiding them from concept to completion with innovative, tailored architectural solutions that bring their visions to life.